Solid Waste Incinerator System Specification

  • Condition
  • New
  • Type
  • Solid Waste Incinerator System
  • Usage
  • Others
  • Structure
  • Single or multi-chamber
  • Pressure
  • Medium Pressure
  • Style
  • Horizontal
  • Material
  • Mild Steel
  • Voltage Requirement
  • 220V - 440V, 3 Phase
  • Fuel Type
  • Diesel, Natural Gas, or LPG
  • Temperature Range
  • Up to 1100C
  • Capacity
  • Ranges from 50 kg/hr to 500 kg/hr
  • Control Panel
  • Digital PLC based
  • Chimney Height
  • 6-15 meters
  • Emission Standard
  • Compliant with international environmental regulations
  • Ignition Method
  • Automatic or Manual
  • Application
  • Hospitals, Municipal solid waste management, Industrial waste
  • Burning Efficiency
  • Above 95%
 

Solid Waste Incinerator System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 8 Units Per Month
  • Delivery Time
  • 2-5 Week
  • Main Domestic Market
  • Madhya Pradesh, Rajasthan, Uttar Pradesh, Haryana, Himachal Pradesh
 

About Solid Waste Incinerator System

THERMAL COMBUSTION ZONE SPECIFICATIONS

System Component

Function

Technical Specifications

Primary Chamber (Volatilization)

Pyrolytic combustion and solid waste gasification under controlled oxygen deficiency.

Operating Temperature: 800 deg C - 850 deg C

Lining: High-alumina refractory lining (IS 8 Grade, 115 mm thick) with insulation bricks.

Secondary Chamber (Reburn)

Complete thermal destruction of unburnt hydrocarbons, volatile gases, and dioxins/furans.

Operating Temperature: 1050 deg C - 1100 deg C

Retention Time: Minimum 2.0 seconds with excess air combustion.

Burner System

Provides required thermal power for ignition and precise temperature maintenance.

Fully automatic dual-fuel (Diesel / Natural Gas / LPG) burners with flame safeguard and auto-ignition.

AIR POLLUTION CONTROL SYSTEM (APCS) SPECIFICATIONS

Equipment / Unit

Function

Technical Specifications

Venturi Scrubber

Rapidly quenches flue gas temperature and traps sub-micron particulate matter (PM).

Stainless Steel (SS-316L / Hastelloy lined) high-energy throat design with atomized water spray nozzles.

Packed Bed Alkaline Scrubber

Neutralizes acidic gases (SOx, HCl, HF) using recirculated caustic (NaOH) liquid spray.

Polypropylene / FRP vessel packed with Pall rings; includes automated pH dosing pump control.

Induced Draft (ID) Fan & Stack

Maintains negative suction pressure across chambers and safely disperses treated flue gases.

SS-316 impeller ID fan.

Stack Height: 30 meters above ground level as per CPCB emission standards.



Experience the outstanding efficiency of our Solid Waste Incinerator System-an illustrious, blue-ribbon solution for hospitals, municipal waste management, and industrial disposal. Renowned as a best-seller among environmental systems, this unit blends cutting-edge technology with reliability. With burning efficiencies above 95% and a capacity ranging from 50 kg/hr to 500 kg/hr, it operates within a temperature range up to 1100C. Engineered with a digital PLC control panel and versatile ignition methods, this scarce bargain promises compliance with international standards, robust performance, and superior waste reduction capabilities.

Versatile Applications & Rugged Material Features

The Solid Waste Incinerator System is perfectly suited for hospitals, industrial waste, and municipal solid waste management. Designed for rigorous usage, it efficiently handles waste disposal with either single or multi-chamber structures. Constructed from durable mild steel, its medium-pressure, horizontal style ensures longevity under demanding conditions. This incinerator is a vital asset wherever secure, compliant, and effective waste processing is required, thanks to its flexibility in fuel types and application scope.


FOB Port & Delivery Details: Customized Quotation

Enjoy seamless procurement with flexible FOB port options across India, tailored to your region upon quotation request. Typical delivery time is prompt, ensuring your blue-ribbon incineration system arrives on schedule. Our sale price reflects a true bargain considering its advanced features, with sample policies available for selected clients-minimizing outlay and ensuring total satisfaction before commitment. Precise details are provided in each customized quotation to ensure clarity throughout your purchasing experience.


FAQ's of Solid Waste Incinerator System:


Q: How does the Solid Waste Incinerator System ensure high burning efficiency?

A: This system operates at burning efficiencies above 95% by utilizing advanced combustion chambers and precise temperature control, resulting in effective waste reduction and minimal residue.

Q: What types of waste can be processed with this incinerator?

A: It is engineered to handle hospital waste, municipal solid waste, and industrial waste, making it suitable for a variety of professional settings and waste disposal needs.

Q: Where is the system manufactured and supplied from?

A: The Solid Waste Incinerator System is manufactured, supplied, and supported by an experienced provider based in India, supplying high-quality systems to clients nationwide and internationally.

Q: What is the process for obtaining a quotation and delivery timeline?

A: You can request a quotation through our sales team with your specific requirements. Upon confirmation, we provide detailed pricing, estimated outlay, and delivery time-typically as per the specified region and order volume.

Q: When should one opt for automatic versus manual ignition methods?

A: Automatic ignition offers ease and efficiency for frequent or large-scale operations, while manual ignition may be preferred in settings where operational flexibility or manual oversight is desired.

Q: What are the benefits of a PLC-based digital control panel?